Barco RS232 Manual do Utilizador Página 45

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 171
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 44
2. Basic Commands
Example
Reads the actual Phase value of the projector, the awnser being \x1a
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x06
Checksum
\x28
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x06
Data [0]
\x1a
Checksum
\x42
Stop
\xff
2.7.35 Minimum Phase, Read
Description
Reads the minimum (range) Phase value of the projector
Command
Command [0]
\x26
Command [1]
\x06
Returned Data
Data [0] = minimum Phase value
Example
Reads
the minimum Phase value of the projector, the awnser being \x00