Barco RS232 Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 171
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
1. Serial communications Basics
’o’
\x6f
’r
\x72
’l’
\x6c
’d’
\x64
NULL
\x00
standard file
Predefined file stored in read-only memory
custom file
File created by the user and stored in non-volatile read write memory
Filename
A filename is specified as a C-language string. This string has to follow some rules:
x x x x x x x x . y z z
NULL
1. length string = 12
2. x = character of the base name formed by max 8 characters
3. y = kind of file (= 1 character)
’s’
standard file
’c’
custom file
4. z = file index (= 2 characters: 0..9)
zz specifies the location in memory where the file is stored.
- for standard files: zz = 00...maximum standard files
- for custom files: zz = 00...63 where 00 is reserved for the file ’none .c00’ (file which is loaded when no signal is applied)
5. yzz is a unique combination. In other words, no two files can exist with the same extension yzz.
To specify more than o ne file you can use the question m ark (?) and (*) wild card character for x, y and z (o r
any other character).
?: This wildcard charac ter can represent any p ossible cha racter on a particular location.
* : This wildcard character can represent any possible character(s) following the wildcard’s position in the
string.
•”ntsc .c01
•”svga_60v.s?7
•”????????.???
”sv*.*”
1.6 Serial comms commands
Basic Commands
Basic commands are the commands used to control the basic parameters of the projector.
The Contrast increm ent command is a basic command.
Advanced Commands
Advanced commands are used to control advanced parameters of the projector.
The Pip loop focus is an advanced parameter
10
R5976884 RLM SERIES 04/04/2006
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 170 171

Comentários a estes Manuais

Sem comentários